PRESC=NODIVISION, LPFMODE=BYPASS, OVSRSEL=X2, WARMUPMODE=NORMAL
Control Register
WARMUPMODE | Warm-up Mode 0 (NORMAL): ADC is shut down after each conversion 1 (FASTBG): Bandgap references do not need warm up, but have reduced accuracy. 2 (KEEPSCANREFWARM): Reference selected for scan mode is kept warm. 3 (KEEPADCWARM): ADC is kept warmed up and scan reference is kept warm |
TAILGATE | Conversion Tailgating |
LPFMODE | Low Pass Filter Mode 0 (BYPASS): No filter or decoupling capacitor 1 (DECAP): On chip decoupling capacitor selected 2 (RCFILT): On chip RC filter selected |
PRESC | Prescaler Setting 0 (NODIVISION): undefined |
TIMEBASE | Time Base |
OVSRSEL | Oversample Rate Select 0 (X2): 2 samples for each conversion result 1 (X4): 4 samples for each conversion result 2 (X8): 8 samples for each conversion result 3 (X16): 16 samples for each conversion result 4 (X32): 32 samples for each conversion result 5 (X64): 64 samples for each conversion result 6 (X128): 128 samples for each conversion result 7 (X256): 256 samples for each conversion result 8 (X512): 512 samples for each conversion result 9 (X1024): 1024 samples for each conversion result 10 (X2048): 2048 samples for each conversion result 11 (X4096): 4096 samples for each conversion result |